Shut down the filter and remove the manhole cover. Unscrew the filter element's tightening nut, remove the pressing plate, take out the filter element, and rinse the inside of the equipment with water until clean.

  The method for disassembling and cleaning the filter is:

  1. Stop the filter, remove the manhole cover. Unscrew the filter element's tightening nut, remove the pressing plate and take out the filter element, then rinse the inside of the equipment with water.

  2. Remove the upper and lower positioning rings at both ends of the filter element and clean them with water.

  3. Insert one end of the cleaned filter element with the positioning ring into the holes of the perforated plate.

  4. Using the pull rod as the axis, fit the pressing plate, insert the upper positioning ring of the filter element into the corresponding hole of the pressing plate, and tighten the tightening nut.

  5. After installing the filter element, reinstall the manhole cover and start the machine to allow water flow.

  6. Open the water inlet valve and the air vent valve. When the equipment is filled with water, open the drain valve and close the air vent valve. Observe the water from the drain outlet; when the water is free of white foam, the cleaning is complete and the equipment can be used normally.

Hot News


Evaporator Working Principle

Evaporator working principle: The heating chamber provides the heat required for evaporation to the liquid, causing the liquid to boil and vaporize; the evaporation chamber completely separates the gas and liquid phases. The vapor generated in the heating chamber carries a large amount of liquid droplets. When it reaches the larger space of the evaporation chamber, these liquids are separated from the vapor through their own condensation or the action of demisters. Usually, the demister is installed at the top of the evaporation chamber. According to the movement of the solution in the evaporator, there are: Circulation type. The boiling solution passes multiple times over the heating surface in the heating chamber, such as central circulation tube type, basket type, external heating type, Lewen type, and forced circulation type. Single pass type. The boiling solution in the heating chamber...

2018-09-28


7 Practical Heat Exchanger Technical Q&A

1. How does a heat exchanger transfer heat? Answer: In the most common wall-type heat exchanger, the main heat transfer methods are conduction and convection. The hot fluid first transfers heat to one side of the tube wall by convection, then the heat is conducted through the tube wall to the other side, and finally, the heat is transferred from the other side of the tube wall to the cold fluid by convection, thus completing the heat transfer process of the heat exchanger. 2. How does the flow velocity of the medium affect the heat transfer effect? Answer: The higher the flow velocity of the medium inside the heat exchanger, the greater the heat transfer coefficient. Therefore, increasing the flow velocity of the medium inside the heat exchanger can greatly improve the heat transfer effect.

2018-09-28


What are the functions of water purifier filters? What impurities can they filter out?

How important is the filter cartridge of a water purifier? Those who have bought a water purifier know that sellers always remind us to replace the filter cartridge regularly and timely. This is because after using the filter cartridge for a certain period, it will consume itself continuously due to filtering too many impurities until it reaches the end of its life. So, what exactly are the functions of the water purifier's filter cartridge? What can it filter? What are the functions of the water purifier filter cartridge? What impurities can it filter? Below, we will introduce the functions of the commonly used reverse osmosis water purifier filter cartridge. Generally speaking, the reverse osmosis water purifier has 5 stages of filter cartridges, which we will understand one by one below.

2018-09-28


How to recover the refrigerant from an industrial chiller to the receiver?

During the maintenance or servicing of industrial chillers, it is necessary to recover the refrigerant before proceeding with subsequent maintenance work. There are two common methods for recovering refrigerant from industrial chillers: one is to recover the refrigerant into a receiver, and the other is to recover it into a refrigerant cylinder. 1. How to recover the refrigerant from an industrial chiller into a receiver? Note: Our industrial chillers are equipped with high/low pressure controllers. When recovering refrigerant, the contacts of the high/low pressure controllers should be kept normally closed to prevent the machine from shutting down due to pressure issues during refrigerant recovery. The refrigerant of the industrial chiller should be...

2018-09-28